Labour Day Special Limited Time Flat 70% Discount offer - Ends in 0d 00h 00m 00s - Coupon code: 70spcl

VMware 5V0-22.23 VMware vSAN Specialist (v2) Exam Practice Test

Page: 1 / 8
Total 75 questions

VMware vSAN Specialist (v2) Questions and Answers

Question 1

A vSAN administrator needs to build a vSAN ESA cluster with RAID-5/FTT 1 adaptive storage policy.

What is the absolute minimum number of hosts that need to be part of that vSAN ESA cluster?

Options:

A.

6 hosts

B.

4 hosts

C.

5 hosts

D.

3 hosts

Question 2

When adding a disk to a host that was previously used in a decommissioned vSAN cluster the intended disk does not show among the available devices in disk management.

Which action should be taken prior to assigning the disk on disk management?

Options:

A.

Format the existing partition

B.

Create a 1GB metadata partition

C.

Delete all device partitions

D.

Create a VMFS partition

Question 3

During yesterday's business hours, a cache drive failed on one of the vSAN OSA nodes. The administrator reached out to the manufacturer and received a replacement drive the following day. When the drive failed, vSAN started a resync to ensure the health of the data, and all objects are showing a healthy and compliant state. The vSAN administrator needs to replace the failed cache drive.

Which set of steps should the vSAN administrator take?

Options:

A.

Physically replace the failed cache device, and vSAN will automatically create a new disk group. Then, remove the disk group with the failed device.

B.

Place the disk group into maintenance mode, and select Full Data Migration. Then, physically replace the failed cache device. Afterwards. vSAN will rebuild the disk group automatically.

C Remove the existing vSAN disk group and physically replace thedevice. Thencheck to verify that the ESXi host automatically detects the new device Afterwardsmanually recreate the Disk Group

C.

Physically replace the failed cache device, and vSAN will automatically allocate the storage. Then, rebalance the cache layer.

Question 4

What are two prerequisites for using the TRIM and UNMAP capability of vSAN? (Choose two.)

Options:

A.

Deduplication and compression are enabled.

B.

The vSAN cluster is an all-flash architecture.

C.

The VM quest operating system supports ATA TRIM or SCSI UNMAP capability

D.

TRIM and UNMAP is enabled.

E.

Change the Object Space Reservation to 100.

Question 5

What is the purpose of host rebuild reserve in vSAN?

Options:

A.

Reserves space for internal operations

B.

Reserves space in case of single host failure

C.

Stores vSphere HA heartbeats

D.

Allocates capacity for vCLS

Question 6

Which vSAN maintenance mode option should be used to avoid storage policy non-compliance?

Options:

A.

Ensure accessibility

B.

Partial maintenance mode

C.

Full data migration

D.

No data migration

Question 7

An organization plans to implement a new vSAN 8.0 cluster to take advantage of the new features around improved I/O flow, better resiliency, and more efficient disk usage. The vSAN ReadyNodes available for the cluster consist of eight NVMe disks.

How should the organization configure the disk layout?

Options:

A.

Use vSAN OSA and create two disk groups with one cache disk and three capacity disks each

B.

Use vSAN ESA and the new Storage pool configuration where all disks contribute to capacity

C.

Use vSAN OSA and thenew Storage pool configuration where all disks contribute to capacity

D.

Use vSAN ESA and create two disk groups with one cache disk and three capacity disks each

Question 8

An administrator wants to assign a storage policy to a workload on a two-node vSAN OSA cluster consisting of three disk groups each with nested fault domains. The virtual machine must be protected against a disk or disk group failure.

Which two storage policies meet these requirements? (Choose two.)

Options:

A.

RAID-5/FTT 2

B.

RAID-1/FTT 3

C.

RAID-6/FTT 2

D.

RAID-5/FTT 1

E.

RAID-1/FTT 1

Question 9

A vSAN administrator is planning to deploy a new vSAN cluster with these requirements:

Question # 9Physical adapters share capacity among several traffic types

Question # 9Guaranteed bandwidth for vSAN during bandwidth contention

Question # 9Enhanced security

Which two actions should be taken to configure the new vSAN cluster to meet these requirements? (Choose two.)

Options:

A.

Create static routes between the vSAN hosts

B.

Use IOPS Limit rules in storaqe policies

C.

Utilize Network I/O Control

D.

Enable jumbo frames

E.

Isolate vSAN traffic in a VLAN

Question 10

A vSAN administrator has an existing cluster where each ESXi host has the following:

Disk group #1 with one cache device and three capacity devices.

Disk group #2 with one cache device and two capacity devices.

What must the vSAN administrator do to expand disk group #2 to have three capacity devices?

Options:

A.

Create a new disk group with a single capacity device and then migrate the existing capacity devices

B.

Add the new capacity device to the disk group and vSAN will automatically rebalance

C.

Put the entire ESXi host in maintenance mode, evacuate all data, then add the new capacity device

D.

Put the disk group in maintenance mode, evacuate all data, then add the new capacity device

Question 11

How often does the Skyline Health interval validate online if there are new Health Checks available for vSAN?

Options:

A.

Every 1 hour

B.

Every 4 hours

C.

Every 24 hours

D.

Every 12 hours

Question 12

An administrator has deployed a new vSAN OSA cluster that contains eight hosts and needs to configure a storage policy for the currently deployed database virtual machines. The requirements state that if two hosts in the vSAN OSA cluster fail, all virtual machines are unaffected.

Which RAID configuration must the administrator use in this storage policy to achieve the best performance for the database virtual machines?

Options:

A.

RA1D-1

B.

RAID-5

C.

RAID-6

D.

RAID-0

Question 13

A host in a vSAN stretched cluster goes offline during an unplanned event.

Which action will be triggered from AQC on the vSAN cluster?

Options:

A.

AQC will trigger a vMotion of VMs that went offline.

B.

AQC will restart the VMs that went offline.

C.

AQC will recalculate the quorum on an object.

D.

AQC will create a vSAN alarm.

Question 14

A vSAN administrator has a cluster configured with a Storage Pool that was moved to a new physical DC.

Upon checking on the vSAN cluster health status, one of the ESXi hosts has two storage devices in a degraded state and must be replaced.

What must the vSAN administrator do to restore the health of the vSAN cluster with minimum risk?

Options:

A.

Remove the host from ySAN configuration, replace the faulty disks, re-create the storage pool

B.

Remove the entire storage pool, install the new devices, re-create the storage pool

C.

Remove the host from the cluster, replace the faulty disks, re-add the host to the cluster

D.

Remove the devices from the storage pool, replace the storage devices, claim the new devices in vSAN

Question 15

An administrator is responsible for managing a five-node vSAN cluster. The vSAN Cluster is configured with both vSphere High Availability (HA) and vSphere Distributed Resource Scheduler (DRS). The vSAN Cluster is currently hosting 150 virtual machines that have consumed 60% of the usable capacity.

Each virtual machine belongs to one of the following vSAN Storage Policies:

vSANPolicy1:

Site Disaster Tolerance: None

Failures to Tolerate: 1 failure - RAID-5 (Erasure Coding)

vSANPolicy2:

Site Disaster Tolerance: None

Failures to Tolerate: No data redundancy

Following an unplanned power event within the data center, the administrator has been alerted to the fact that one host has permanently failed.

What will be the impact to any virtual machine that was running on the failed host using vSANPolicy1?

Options:

A.

Each virtual machine will be restarted on another vSAN host usingvSphere HA.

B.

Each virtual machine will be unavailable for up to 90 minutes while the automatic recovery process completes.

C.

vSAN will defer the start of the recovery process for 60 minutes, and the virtual machines will not power on until the recovery process has been completed.

D.

Each virtual machine must be restored from backup.

Question 16

A site administrator wishes to implement HCI mesh between two clusters on vSAN that are located in geographically separate sites and which are administered within a single datacenter.

Which two requirements should the vSAN administrator consider to accomplish this goal? (Choose two.)

Options:

A.

Either Layer 2 or Layer 3 communications can be used

B.

A leaf spine topology is required for core redundancy and reduced latency

C.

NIC teaming must be implemented for the vSAN network vmkernel port

D.

The configuration must meet the same latency and bandwidth requirement as local vSAN

E.

Encryption must be disabled prior to configuring HCI mesh

Question 17

Which two considerations should an architect assess when designing a HCI Mesh solution with VMware vSAN and VMware vSphere High Availability (HA)? (Choose two.)

Options:

A.

A server vSAN cluster can serve its local datastore up to five client vSAN clusters.

B.

A client cluster can mount up to ten remote datastores from one or more vSAN server clusters.

C.

A minimum of three nodes are required within the client cluster for vSphere HA to work

D.

If vSphere HA is to work with HCI Mesh, Datastore with Permanent Device Loss (PDL) must be confiqured to Power off and restart VMs.

E.

If vSphere HA is to work with HCI Mesh, Datastore with AllPaths Down (APD) must be configured to Power off and restart VMs.

Question 18

A vSAN administrator has a group of requirements from the application team, which mandates spreading the components across storage devices as much as possible.

What should the vSAN Administrator consider to achieve such a requirement for building a new vSAN cluster? (Choose two.)

Options:

A.

Configure disk striping in OSA

B.

Configure disk striping in ESA

C.

Enable Force Provisioning in OSA

D.

Enable deduplication for vSAN

E.

Create a dedicated Storage Pool in ESA

Question 19

A vSAN administrator is tasked to perform an upgrade of a vSAN cluster, including firmware and drivers for its hardware. The vSAN administrator already created an image using vSphere Lifecycle Manager (vLCM).

Prior to selecting Start Remediation, which step should be taken to upgrade the complete vSAN cluster as a single task?

Options:

A.

Select Remediate All through vLCM to upgrade all hosts in the cluster

B.

Place all hosts in the vSAN cluster into Maintenance Mode

C.

Stage the upgrade of the vSAN cluster through vLCM

D.

Manually remediate one host at a time in the vSAN cluster

Question 20

A six-node vSAN ESA cluster contains multiple virtual machines, and a vSAN storage policy with the rule "Failures to tolerate" set to "1 failure - RAID-5 (Erasure Coding)" is assigned. A vSAN administrator has changed the rule in the assigned policy to "2 failures - RAID-6 (Erasure Coding)".

What is the result of this change?

Options:

A.

No changes occur until the policy is reapplied.

B.

The changes are queued for 60 minutes.

C.

The policy change is rejected immediately.

D.

The updated policy is serially applied to the virtual machines.

Question 21

Refer to the exhibit.

An administrator uses SSH to log into a vSAN ESA host and runs theesxcli vsan debug object overviewcommand.

Question # 21

The administrator notices the Healthy Components column, the last column, is reporting some components are not in a fully healthy state.

What could cause this behavior?

Options:

A.

New physical disks have been claimed and a rebalance operation is underway.

B.

The applied Storage policy has been updated.

C.

New VMDKs have been added to multiple VMs, but the storage policy has not finished applying.

D.

One host is in maintenance mode with ensure accessibility.

Question 22

An administrator has been tasked with upgrading existing vSAN OSA cluster hosts with a SSD cache device per host to a NVMe device (hot plug).

Which fact should guide the administrator's action?

Options:

A.

The disk groupmust be deleted on each physical host in the vSAN OSA cluster to use the NVMe device.

B.

The disk group does not need to be removed before adding new cache.

C.

The host must be removed from vSAN OSA cluster before changingcache devices.

D.

The cache disk drives must have a larger capacity.

Page: 1 / 8
Total 75 questions