Big Cyber Monday Sale Limited Time Flat 70% Discount offer - Ends in 0d 00h 00m 00s - Coupon code: 70spcl

VMware 2V0-13.25 VMware Cloud Foundation 9.0 Architect Exam Practice Test

Page: 1 / 10
Total 97 questions

VMware Cloud Foundation 9.0 Architect Questions and Answers

Question 1

Which type of design would include specific details about server hardware, port connections, or Fibre Channel zones?

Options:

A.

Logical

B.

Service

C.

Physical

D.

Conceptual

Question 2

During the design workshop, the customer stated the following requirement:

• The solution must comply with the organization's security standards.

Which two design decisions should be included in the logical design for the workload domain? (Choose two.)

Options:

A.

Use large-size NSX Edge virtual appliances to account for the additional firewall rules.

B.

Enable VM Monitoring for each workload within the cluster.

C.

Enable Inter-SR iBGP routing.

D.

Use an SHA-2 algorithm or higher when signing certificates.

E.

Establish an operations practice to capture and update the thumbprint of the NSX Local Manager certificate on the NSX Global Manager every time the certificate is updated.

Question 3

An architect had been given a constraint to use an existing storage array to support the virtual infrastructure design project.

The architect documents the following:

    Assumption 01: The existing storage array has sufficient capacity and performance to support the intended workloads.

    Risk 01: There is a risk that the performance and capacity of the existing storage array may not be sufficient for the solution.

How would the architect mitigate the risk?

Options:

A.

Ensure that the customer allocates budget for new hardware in case the risk is realized.

B.

Setup a RAID mirror configuration on the existing storage array for redundancy.

C.

Ignore the constraint and design the solution using VMware vSAN Express Storage Architecture (ESA).

D.

Request for additional budget to purchase more Fibre Channel switches.

Question 4

Requirements:

    Workloads across multiple datacenters (DC01, DC02)

    Support two-factor authentication (2FA)

    Reduce operational overhead

Which two design decisions should be documented for the VCF Single Sign-On (SSO) architecture?

Options:

A.

Deploy VIDB in the management domain of every VCF instance in all sites.

B.

Deploy VIDB in the management domain of each VCF instance at DC02.

C.

Configure all additional VCF instances in the same region to point to the VIDB in the first VCF instance at DC02.

D.

Deploy VIDB in the first VCF instance management domain at DC01.

E.

Configure all additional VCF instances in the same private cloud to point to the VIDB in the first VCF instance at DC01.

Question 5

An architect is responsible for designing a new VMware Cloud Foundation (VCF)-based Private Cloud solution. During the requirements gathering workshop with key customer stakeholders, the following information was captured:

• The solution must ensure that all components meet a software version of N-1.

Options:

A.

Recoverability

B.

Manageability

C.

Security

D.

Availability

Question 6

An architect is responsible for designing a VMware Cloud Foundation (VCF) Private Cloud. During a requirements gathering workshop with key customer stakeholders, the following information was captured:

• The service catalog solution must meet a minimum availability SLA of 99.9%.

• The performance of the service catalog solution must not be impacted by maintenance activities or a single physical ESXi host failure.

During the logical design phase of the project, the following design decisions were made:

• The solution will deploy VCF Automation using the highly available deployment model.

Which two corresponding physical design decisions should the architect make to meet the stated requirements? (Choose two.)

Options:

A.

The solution will configure the external load balancer to send all traffic to the native Kubernetes load balancer.

B.

The solution will deploy three VCF Automation appliances using the small size.

C.

The solution will create a VM-host affinity rule to ensure all nodes of the VCF Automation cluster are located on the same ESXi host.

D.

The solution will create a VM-host anti-affinity rule to ensure all nodes of the VCF Automation cluster are located on different ESXi hosts.

E.

The solution will deploy an external load balancer to replace the native load balancer.

Question 7

An architect is responsible for the design of a VMware Cloud Foundation (VCF) Fleet and the following risk has been identified:

RISK001: There is a risk that frequent infrastructure design changes may break Disaster Recovery (DR) plans and Service Level Objectives.

What should the architect suggest to mitigate this risk?

Options:

A.

Setup monitoring & alerting against defined infrastructure service level objectives.

B.

Develop a process to review and update DR plans between changes and schedule monthly end-to-end DR tests.

C.

Limit infrastructure design change frequency to a maximum of once a month.

D.

Configure VM replication with recovery point objective of 5 minutes or less for all workloads from the primary to DR site.

Question 8

An architect is working on a VMware Cloud Foundation (VCF) architecture design and identified the following requirements:

• The organization is using a third-party virtual appliance that does not support overlay networks.

• The virtual appliance must reside on the same L2 domain as an external physical firewall.

• The virtual appliance also needs access to workloads that are currently hosted on overlay segments provided by NSX.

Which design decision should the architect make to meet these requirements?

Options:

A.

Request the third-party vendor to certify the virtual appliance for NSX Overlay segments.

B.

Connect the virtual appliance to a VLAN-backed segment and configure NSX bridging to allow access to overlay segments.

C.

Place the virtual appliance and all workloads on VLAN-backed segments.

D.

Connect the virtual appliance to an overlay-backed segment and use static routes to the firewall.

Question 9

An architect is planning resources for a new cluster that will be part of an existing workload domain. The new cluster will provide resources for several new workloads, including a mission-critical application consisting of five resource-intensive virtual machines.

The following requirements were provided for the new cluster:

• The solution must ensure that the new workload cluster meets the company's availability standard of N+1.

• The solution must minimize the overall investment in hardware.

Which two design recommendations should the architect make to meet the stated requirements? (Choose two.)

Options:

A.

Use automated placement rules to keep the mission-critical application virtual machines apart.

B.

Use resource pools to prioritize resource for the mission-critical application virtual machines.

C.

Use automated placement rules to keep the mission-critical application virtual machines together.

D.

Create a cluster with six hosts.

E.

Create a cluster with five hosts.

Question 10

Discovery: Multiple business units (some from acquisitions) with separate AD instances. Each unit operates independently and requires dedicated development environments.

Requirement: Provide self-service provisioning through VCF Automation.

Which two design decisions should be included? (Choose two.)

Options:

A.

All tenants will be configured to use the corporate AD instance for authentication.

B.

All tenants will be configured to use their dedicated AD instance for authentication.

C.

A VCF Automation tenant will be created for each business unit.

D.

A VCF Automation project will be created for each business unit.

E.

All projects will be configured to use their dedicated AD instance for authentication.

Question 11

An architect is working with an organization on the creation of a new VMware Cloud Foundation (VCF) Private Cloud. The organization has provided the following business objectives:

    Reduce costs of duplicate systems.

    Eliminate risks of unsupported platforms.

    Reduce public cloud costs.

    Eliminate risks from poor documentation.

Use cases: Migration, Containerization, Centralization & Consolidation.

When considering these objectives and use cases, what should the architect include in the design documentation as a part of the Conceptual Model?

Options:

A.

A constraint that the solution must be accessible via a HTTPS GUI to all relevant areas of the business.

B.

A requirement that the solution will provide support for provisioning and managing workloads based on virtualization and containerization technologies.

C.

An assumption that a complete mapping of application dependencies is not available.

D.

A risk that the solution may not support the migration of containerized workloads.

Question 12

During a VMware Cloud Foundation (VCF) architectural design workshop, one of the stakeholders made the following comment:

    “The company has just used the remaining budget to purchase eight vSAN Ready Nodes for this project.”

How would the architect classify this statement within the conceptual model document?

Options:

A.

Requirement

B.

Risk

C.

Assumption

D.

Constraint

Question 13

As a part of designing the VMware Cloud Foundation (VCF) Operations deployment, the architect must ensure that VCF Operations is capable of monitoring the customer's infrastructure made up of a central datacenter and multiple remote sites in different countries.

During a design workshop, the following requirements were identified:

    REQ‑001: Corporate IT users must be able to review performance, alerts, and capacity details from a single management point.

    REQ‑002: The monitoring solution must support local data collection at remote sites to prevent data loss from unstable WAN connections.

    REQ‑003: The monitoring solution must comply with local data sovereignty regulations.

Which deployment model fulfills all design requirements?

Options:

A.

Single VCF fleet with Cloud Proxies in each remote site

B.

Each remote site will be its own VCF fleet.

C.

All remote sites will be a single VCF fleet.

D.

A single fleet with multiple VCF instances

Question 14

Which four component areas are provided by a VMware Kubernetes Service (VKS) cluster?

Options:

A.

Identity federation, persistent logging, firewall services, and monitoring.

B.

Authentication, external storage, virtual machine networking, and DNS services.

C.

Authorization, backup services, VLAN segmentation, and DHCP.

D.

Authentication and authorization, storage integration, pod networking, and load balancing.

Question 15

Existing environment:

    3 vSphere clusters, 5 hosts each.

    Networking = vDS.

    Storage = NFSv3.

    Managed by single vCenter.Architect decides to create a new VCF fleet with a single VCF instance.

What design implication should be documented?

Options:

A.

NSX will be automatically deployed during the creation of the VCF fleet.

B.

The vCenter VM must be migrated to a standalone host before fleet creation.

C.

The clusters will be automatically configured to use vSAN storage before the creation of the fleet.

D.

The ESX hosts will be converted to use vSphere Lifecycle Manager baselines during the creation of the fleet.

Question 16

A VMware Cloud Foundation (VCF) architect is planning for the expansion of an existing VCF instance.

The existing VCF instance is deployed with a single workload domain. The number of ESXi hosts has grown to the maximum number the existing vCenter can support.

Which design decision would the architect need to make to allow the existing VCF Instance to add more ESXi hosts?

Options:

A.

Deploy a second vCenter server appliance within the existing workload domain

B.

Deploy a second workload domain within the existing VCF Instance

C.

Deploy a second cluster within the existing vCenter

D.

Deploy a second VCF Instance within the existing VCF Fleet

Question 17

Which VMware Cloud Foundation (VCF) Storage Model can be deployed to scale storage capacity independent of compute and network?

Options:

A.

vSAN Compute Cluster Storage Model

B.

vSAN ESA Storage Model

C.

vSAN Capacity Cluster Model

D.

vSAN ESA Storage Cluster Model

Question 18

VMware Kubernetes Service (VKS) cluster exposes three layers of controllers to manage its lifecycle.

Which set correctly identifies these layers?

Options:

A.

Virtual Machine Service, vCenter Appliance, Supervisor Service.

B.

Cluster API, Node Problem Detector, CNI Plugin.

C.

API Gateway, StatefulSet Controller, Ingress Controller.

D.

Virtual Machine Service, Cluster API, and Cloud Provider Plugin.

Question 19

During the design workshop, the customer stated the following requirement:

• The solution will support secure communication.

Which design decision should be included in the logical design for the workload domain?

Options:

A.

Use a SHA-2 algorithm or higher for signed certificates.

B.

Set promiscuous mode port group security policy to reject.

C.

Verify all physical components used for the deployments are on the hardware compatibility list.

D.

Ensure the host servers have TPM 2.0 hardware.

Question 20

An architect responsible for creating the automation design for a VMware Cloud Foundation (VCF) Private Cloud is reviewing the notes from a customer design workshop. The customer has provided the following information:

• The customer's existing fleet management instance will be upgraded to maintain the existing process for virtual machine deployments.

• The customer would like to limit the total active resource consumption per VCF Automation user.

• The customer would like to ensure requests meet company requirements prior to deployment for certain users.

A combination of which two VCF Automation policies should the architect recommend to meet the customer's stated requirements? (Choose two.)

Options:

A.

IaaS Policy

B.

Approval Policy

C.

Resource Quota Policy

D.

Deployment Limit Policy

E.

Lease Policy

Question 21

An architect is responsible for designing a VMware Cloud Foundation (VCF)-based private cloud. During the design requirements gathering workshop, the following information was captured:

• The solution must capture events from all infrastructure components of the VCF fleet.

• The solution must provide a single pane of glass management interface for troubleshooting, alerting, and monitoring using metrics, events, and flows.

• The solution must meet a 99.9% Service Level Agreement for Availability.

Which three design decisions should the architect make to meet the stated requirements? (Choose three.)

Options:

A.

Configure VCF Operations for logs to capture events from only VCF Management components.

B.

Configure the integration for VCF Operations and VCF Automation.

C.

Deploy VCF Operations for logs in a Simple model.

D.

Configure the integration for VCF Operations and VCF Operations for logs.

E.

Configure VCF Operations for logs to capture events from all VCF infrastructure components.

F.

Deploy VCF Operations for logs in a High Availability model.

Question 22

An architect is responsible for designing a new VMware Cloud Foundation (VCF)-based private cloud. During the discovery workshops, the following information was captured from key customer stakeholders:

    The private cloud will operate with three different monitoring levels:

      Self-Managed Service: VM construct only

      OS Managed Service: OS metrics and VM construct

      Fully Managed Service: Infrastructure apps + OS metrics + VM construct

Approved infrastructure applications include: Microsoft IIS, SQL Server, MySQL, PostgreSQL, Tomcat Server, and Apache HTTPD

Each workload must subscribe to a monitoring level

Minimal management overhead is required for agent operations

Which two design decision should the architect make to meet the stated monitoring requirements? (Choose two.)

Options:

A.

Configure the Service Discovery for all workloads that subscribe to the Self-Managed service

B.

Deploy the Managed Telegraf Agent for all workloads that subscribe to the Fully Managed service

C.

Deploy the Managed Telegraf Agent for all workloads that subscribe to the OS Managed service

D.

Deploy the Managed Telegraf Agent for all workloads that subscribe Self-Managed service

E.

Deploy the Open Source Telegraf Agent for all workloads that subscribe to the Fully Managed service

Question 23

An architect is gathering business requirements for a new VMware Cloud Foundation (VCF) solution from the customer stakeholders and subject matter experts.

Which two factors should the architect discuss with the customer to determine any potential impact on the business requirements? (Choose two.)

Options:

A.

Service-level agreements (SLAs)

B.

Product versions

C.

Organizational structure

D.

Average virtual machine size

E.

Storage capacity

Question 24

As part of an initial stakeholder meeting, one of the stakeholders has stated the following:

    The initial design must be completed within the next 3 months so that hardware can be ordered within the current budget cycle.

How would the architect classify and record this statement?

Options:

A.

A constraint

B.

A risk

C.

An assumption

D.

A requirement

Question 25

As part of a design for a VMware Cloud Foundation (VCF) solution, an architect has documented the following dependencies and constraints:

    CONSOOl - Internet access will not be permitted from anywhere within the VCF solution.

    CONS002 - The password must not be stored in plain text anywhere within the VCF solution.

    DEP001 - The customer must make the required VCF binaries accessible to the VCF Installer appliance during the deployment phase.

Which design decision should the architect include in the design for the download of the VCF binaries?

Options:

A.

The VCF Installer appliance will be configured to connect to an online depot.

B.

The VCF Installer appliance will be configured to connect to an offline depot.

C.

The Bundle Transfer Utility will be used on the VCF Installer appliance.

D.

The VCF Download Tool will be used on the VCF Installer appliance.

Question 26

An organization is evacuating their current datacenter and moving all workloads to a new datacenter. The organization has a total of 800 workloads to move, and the migration must be completed with no downtime within a planned change window that is scheduled to occur in four weeks.

What migration method will meet the requirements?

Options:

A.

Cross vCenter vMotion

B.

HCX OS Assisted Migration

C.

HCX Bulk Migration

D.

HCX Replication Assisted vMotion

Question 27

An architect is designing a VMware Cloud Foundation (VCF) deployment to meet the following design requirements:

• Tenants need dedicated external network access.

• The number of NSX Edge clusters should be minimized.

To fulfill these requirements, the architect made a design decision to use a Workload Networking VPC with Full Services Model.

Which additional design decision should be considered as part of the logical network design?

Options:

A.

Deploy the maximum number of 10 NSX Edges into a single Edge cluster.

B.

Install two NSX bare metal Edges with multiple physical interfaces to separate tenants.

C.

Use Virtual Routing and Forwarding (VRF) lite to create a separate VRF TO Gateway for each tenant.

D.

Use NSX Federation providing a dedicated NSX instance for each tenant.

Question 28

A customer is deploying VMware Cloud Foundation (VCF) in an enterprise environment. During a series of workshops with stakeholders, the following requirements were identified:

    The network solution must be capable of complete logical isolation.

    The network solution must be capable of supporting independent upgrade cycles for network stacks.

    The network solution must be capable of tenant-specific customization of NSX configurations.

The architect has made the following design decisions:

    The solution will consist of a single VCF instance.

    The solution will include a management domain and two workload domains.

Based on the scenario, which additional design decision meets all of the stated requirements?

Options:

A.

Deploy NSX only in the management domain and use VLAN-backed segments in the workload domains.

B.

Use a global NSX Federation configuration across workload domains.

C.

Use a shared NSX instance across both workload domains.

D.

Deploy a dedicated NSX instance per workload domain.

Question 29

An architect is responsible for designing a VMware Cloud Foundation (VCF)-based private cloud for a customer. The architect noted the following requirements during a design workshop:

    Co-locate application workloads with VCF management component workloads within the same vSphere cluster.

    Shared storage data is always available and 100% current in the event of a single site outage.

    Have two sites available no more than 10 miles apart (10ms latency) connected with high-speed network technology to host their virtual infrastructure.

    Protect against outages of a single site designated as an availability zone.

Which two storage technologies could meet the stated requirements? (Choose two.)

Options:

A.

NVMe over TCP

B.

NVMe over Fibre Channel (FC)

C.

VMFS on Fibre Channel (FC)

D.

vSAN

E.

vSphere Virtual Volumes (vVols)

Page: 1 / 10
Total 97 questions