Labour Day Special Limited Time Flat 70% Discount offer - Ends in 0d 00h 00m 00s - Coupon code: 70spcl

Oracle 1z0-1091-22 Oracle Utilities Meter Solution Cloud Service 2022 Implementation Professional Exam Practice Test

Page: 1 / 5
Total 51 questions

Oracle Utilities Meter Solution Cloud Service 2022 Implementation Professional Questions and Answers

Question 1

Which TWO statements are true about the Measurement Reprocessing functional?

Options:

A.

When a meter multiplier changes retroactively, measurements are reprocessed, triggering billing adjustment notifications that are sent to the customer information systems.

B.

When an installation constant changes retroactively for a meter, measurements are

automatically reprocessed, triggering billing adjustment notifications that are sent to the customer information systems.

C.

Measurement reprocessing is executed by users manually, which imports corrected initial measurement data (IMD) records.

D.

Derived measurements are recalculated based on new data.

Question 2

You want to manage additional Landis + Gyr device events that are not covered by the set of standard device event types provided with Smart Grid Gateway (SGG).

Apart from creating the new device event type "admin data", what else should you do to represent the new standard device events that you want to manage?

Options:

A.

Set up service providers for each new device event that you want to manage, and specify on each service provider the standard device evert to which it maps.

B.

Create a set of admin data to represent the Landis + Gyr specific device event types, ensuring that for each new device event type, the name of the corresponding standard device event business object is configured in the "Standard Device Event BO Map" characteristic.

C.

Add a record into the External Device Event Mapping table (Dl-E>ODVCEVNTMAP) for each new device event that you want to manage, specifying the standard device event to which it maps.

D.

Extend the Landis + Gyr device event mapping extendable lookup such that it maps each of the Landis -f- Gyr specific device event names to the new standard device event names.

Question 3

What are the THREE uses of the Smart Grid Gateway (SGG)?

Options:

A.

Sharing event information with downstream systems

B.

Sharing customer information

C.

Connecting to Smart Meter systems

D.

Communicating directly with meters

E.

Sharing outage information with outage management systems

Question 4

A time-of-use (TOU) template's interval size controls the values allowed as start and end times. A template can be used to generate TOU data for TOU maps whose seconds per interval (SPI) is divisible by the template's SPI.

For what can you use a 60-minute template?

Options:

A.

To only generate TOU data for 30-minute TOU maps.

B.

To generate TOU data for 6G-, 15-, and 5-minute TOU maps.

C.

To generate TOU data for 120-minute TOU maps.

D.

To only generate TOU data for minute TOU maps.

E.

To generate TOU data for 120-minute and 1440-minute TOU maps.

Question 5

Usage transactions can contain date breaks. What is used to supply date breaks?

Options:

A.

Usage subscription BO

B.

Requesting system or user input

C.

Usage subscription type

D.

Deferred monitor calculation algorithm

Question 6

The interval proxy day estimation Validation, Estimation, and Editing (VEE) rule estimates missing intervals by selecting interval data to average from a list of days that are most like the day being estimated. This is achieved by measuring the component comparison periods.

What is used to define the proxy?

Options:

A.

Like premise

B.

Weather data

C.

Neighbor

D.

Customer class profile

Question 7

Which THREE are best practices for measurement retention?

Options:

A.

Derive time-of-use (TOU) values with interval data to prevent storing extra data.

B.

Derive demand from interval data to prevent storing extra data.

C.

Keep scalar measurements in the customer read tables to stay consistent.

D.

Use Information Lifecycle Management (ILM) processes to help archive data.

E.

Keep initial measurement data (IMD) for the same period of time as final measurements for cancel rebill purposes.

Page: 1 / 5