International Code Council M2 Commercial Mechanical Inspector Exam Practice Test

Page: 1 / 5
Total 50 questions

Commercial Mechanical Inspector Questions and Answers

Question 1

Infrared radiant heaters shall be installed:

Options:

A.

in accordance with UL 2158.

B.

in accordance with UL 1240.

C.

with a 6-ft. clearance on all sides.

D.

with clearances from combustible material in accordance with the manufacturer’s installation instructions.

Question 2

What is the minimum distance required between a combustion air opening at the exterior of a building and a lot line?

Options:

A.

2 feet

B.

3 feet

C.

8 feet

D.

10 feet

Question 3

Termination of vents for appliances listed for and installed outdoors that incorporate integral venting shall:

Options:

A.

terminate not less than 5 feet vertically above the lowest connected appliance draft hood outlet or flue collar.

B.

terminate not less than 5 feet vertically above the highest connected appliance draft hood outlet or flue collar.

C.

be installed in accordance with their listings and the manufacturer’s installation instructions.

D.

be installed in accordance with the design professional’s plans as approved by the local building official.

Question 4

Air mechanically exhausted from a room must be:

Options:

A.

filtered.

B.

recirculated.

C.

discharged into the attic.

D.

discharged to the outdoors.

Question 5

Given: Fabricated of type 430 stainless steel.

Question # 5

Question # 5

Optional type _____ stainless steel is available.

Options:

A.

301

B.

303

C.

304

D.

316

Question 6

The minimum size for access openings for fire dampers shall be:

Options:

A.

the same as the dimension of the duct.

B.

one-half the diagonal of the access opening.

C.

adequate to permit maintenance and resetting of the damper.

D.

12 inches by 12 inches.

Question 7

Pipe and duct insulation can be used within plenums except:

Options:

A.

where the assembly has been tested to UL 723.

B.

where the flame spread index is not more than 25.

C.

where the assembly has been tested to ASTM B84.

D.

where the assembly has been tested to ASTM E84.

Question 8

Exhaust outlets that terminate at a temperature exceeding 600°F shall be designed as a:

Options:

A.

Class I duct.

B.

Class II duct.

C.

Class III duct.

D.

single-wall metal chimney.

Question 9

Exhibit:

Question # 9

CEF-5 is a ceiling exhaust fan manufactured by:

Options:

A.

G.E.

B.

Carnes

C.

Markel

D.

Nutone

Question 10

What is the maximum distance allowed below the design flood elevation from which ventilation may be obtained?

Options:

A.

0 inches

B.

6 inches

C.

1 foot

D.

2 feet

Question 11

The optional integral clearance reduction system is designed to meet which NFPA standard?

Question # 11

Question # 11

Options:

A.

33

B.

72

C.

92A

D.

96

Question 12

When a furnace is installed in a 66-inch-high attic, the maximum distance from the passageway access to the furnace shall be _____ ft., measured along the centerline of the passageway.

Options:

A.

10

B.

15

C.

20

D.

50

Question 13

Supports for hazardous exhaust duct shall be constructed of:

Options:

A.

plastic.

B.

fibrous material.

C.

noncombustible material.

D.

material complying with UL 181.

Question 14

Shutoff valves in plastic pipe ground-source heat pump loop systems shall be installed on both sides of which one of the following?

Options:

A.

Expansion tanks

B.

Heat-fusion joints

C.

Change-in-material joints

D.

Pressure-reducing valves

Question 15

Exhaust is required for which of the following areas?

Options:

A.

Gambling casinos

B.

Office break rooms

C.

High school locker rooms

D.

Prison guard stations