Month End Sale Limited Time 75% Discount Offer - Ends in 0d 00h 00m 00s - Coupon code: peak75

International Code Council 93-Tall-Mass-Timber-Buildings 93-Tall-Mass-Timber-Buildings Exam Practice Test

93-Tall-Mass-Timber-Buildings Questions and Answers

Question 1

Refer to the exhibit by clicking on the EXHIBIT button above.

Question # 1

Given: The connections between the glulam beam and CLT panels all require a fire-resistance rating of 2 hours, and wood cover is designed per AWC Technical Report 10 to provide the entire 2 hours of protection.

The bearing area between the CLT and glulam is the minimum required.

What are the minimum dimensions, in inches, for the wood block shown in red?

Options:

A.

1.5 x 1.5

B.

2 x 2

C.

3 x 3

D.

4 x 4

Question 2

Each of the following is true regarding the fire-resistance rating for exterior bearing walls except:

Options:

A.

Type IV-C must be 1 hour

B.

Type IV-A must be 3 hours

C.

Type IV-B must be 2 hours

D.

Type IV-C must be 2 hours

Question 3

The building owner shall be responsible for each of the following for fire safety during construction except:

Options:

A.

completion of a daily fire safety inspection at the project site by the site safety director.

B.

documentation and maintenance on-site of each inspection’s results until a certificate of occupancy has been issued.

C.

securing documentation in a fire- and water-resistant safe until a certificate of occupancy has been issued.

D.

making documentation immediately available on-site for presentation to the fire code official upon request.

Question 4

Periodic special inspection of sealants or adhesives shall be conducted where sealants or adhesives are part of a mass timber building element as designated in the approved construction documents.

All of the following statements are correct in reference to sealants or adhesives in mass timber buildings except:

Options:

A.

Sealants shall meet the requirements of ASTM C920.

B.

Adhesives shall meet the requirements of ASTM D3498.

C.

Special inspection of mass timber sealing requirements also apply to joints.

D.

Sealants at abutting edges and intersection of mass timber buildings need periodic inspections.

Question 5

Combustible construction forming concealed spaces shall be protected with noncombustible protection with an assigned time of 40 minutes in which construction type?

Options:

A.

Type IV-A

B.

Type IV-B

C.

Type IV-C

D.

Type IV-HT

Question 6

Refer to the figure by clicking on the EXHIBIT button above.

Question # 6

Question # 6

In Type IV-B construction, unprotected portions of mass timber as shown in the Figure are required to be separated by _____ feet.

Options:

A.

12

B.

15

C.

18

D.

20

Question 7

One code-recognized method for calculating the fire-resistance rating of exposed wood members and decking is:

Options:

A.

ACI 216.1

B.

TMS 0216

C.

ASCE 29 Chapter 5

D.

AWS NDS Chapter 16

Question 8

Which of the following is an acceptable alternative for protecting structural connections from fire in Type IV-A, IV-B or IV-C construction?

Options:

A.

Testing of connections in accordance with ASTM E136

B.

Limiting connections to those incorporating wood-on-wood bearing

C.

Using connectors that are rated by the manufacturer for fire performance

D.

Engineering analysis showing limited temperature rise at the connector for the required fire-resistance time of connected members

Question 9

Where Type X gypsum board serves as noncombustible protection for interior surfaces of wall and ceiling assemblies, all of the following code provisions are correct except:

Options:

A.

Screws shall penetrate at least 1 in. into mass timber.

B.

Screws shall be spaced 12 in. on center in both directions.

C.

Panel edges of any layer shall be offset 18 inches from those of the previous layer.

D.

Panel edges of the base layer shall be taped and finished with joint compound.

Question 10

Refer to the figure by clicking on the EXHIBIT button above.

Question # 10

Question # 10

In Type IV-B construction, based on a 900 sq. ft. floor area, a 30 ' room width, and a 12 in. x 18 in. beam as shown in the Figure, the maximum length of the unprotected portion of the mass timber ceiling (dimension X) is _____ feet.

Options:

A.

2

B.

4

C.

6

D.

8

Question 11

Fire-resistance ratings of members and assemblies can be established by all of the following except:

Options:

A.

calculations per IBC Section 722.

B.

fire-resistance testing in accordance with ASTM E84.

C.

fire-resistance designs documented in approved sources.

D.

prescriptive designs of fire-resistance-rated building elements, components or assemblies as prescribed in IBC Section 721.

Question 12

Mass timber is allowed in which of the following International Building Code Construction Types?

Options:

A.

Types I, II, and IV only

B.

Types III and IV only

C.

Types IV and V only

D.

Types I, II, III, IV, and V

Question 13

Refer to the exhibit by clicking on the EXHIBIT button above.

Question # 13

In the detail shown and according to AWC Technical Report 10, what is the time assigned in minutes to 5/8 in. Type X gypsum board for connection fire protection thermal separation requirements?

Options:

A.

Both layers = 20

B.

Both layers = 40

C.

Layer adjacent to the connection = 20 and second layer = 40

D.

Layer adjacent to the connection = 40 and second layer = 20

Question 14

In Type IV-C construction, the fire-resistance rating provided by protection over a connection can be determined by which of the following?

Options:

A.

Testing the fasteners used in the assembly.

B.

Testing the protection covering the connection.

C.

Calculating the temperature rise of the structural element being protected.

D.

Calculating the temperature rise of the supported member used in the connection.

Question 15

Regarding water supply for the protection of buildings under construction, when combustible building materials of the building under construction are delivered to a site, the minimum fire flow provided shall be _____ gpm.

Options:

A.

100

B.

200

C.

500

D.

750

Question 16

Refer to the figure by clicking on the EXHIBIT button above.

Question # 16

Question # 16

In Type IV-B construction, unprotected portions of mass timber as shown in the Figure is limited to an area equal to not more than what percentage of the base floor area?

Options:

A.

15%

B.

20%

C.

30%

D.

40%

Question 17

Periodic special inspection of sealants or adhesives as specified by the International Building Code Section 703.7 shall be conducted at which of the following locations?

Options:

A.

At “joints” as defined in IBC Section 202.

B.

Where they are a required component of a tested fire-resistance-rated assembly.

C.

At abutting edges and intersections of mass timber building elements required to be fire-resistance rated.

D.

At abutting intersections of mass timber building elements and building elements of other materials where one or the other are required to be fire-resistance rated.

Question 18

Refer to the figure by clicking on the EXHIBIT button above.

Question # 18

Question # 18

In Type IV-B construction, unprotected portions of mass timber as shown in the Figure is limited to an area equal to not more than what percentage of the base floor area?

Options:

A.

15%

B.

20%

C.

30%

D.

40%

Question 19

Which of the following requires continuous special inspection?

Options:

A.

Bolted connections

B.

Concealed connections

C.

Anchorage of mass timber construction to deep foundation systems

D.

Adhesive anchors installed horizontally resisting sustained tension loads

Question 20

Refer to the exhibit by clicking on the EXHIBIT button above.

Question # 20

In the detail shown, if the connections between the glulam beam and CLT panels all require a fire-resistance rating of one (1) hour and the wood cover is designed per AWC Technical Report 10 to provide the entire 1 hour of protection, what is the minimum thickness and number of layers required for the locations shown in red?

Options:

A.

1 layer of 1/2 in. Type X

B.

2 layers of 1/2 in. Type X

C.

1 layer of 5/8 in. Type X

D.

2 layers of 5/8 in. Type X

Question 21

Which of the following provisions for mass timber used for interior exit and elevator hoistway enclosures is true?

Options:

A.

Type IV-A construction requires at least 80 minutes of the 120-minute fire-resistance rating to be provided by noncombustible protection.

B.

Type IV-B construction requires at least 40 minutes of the 120-minute fire-resistance rating to be provided by noncombustible protection.

C.

Type IV-C construction requires at least 40 minutes of the 60-minute fire-resistance rating to be provided by noncombustible protection.

D.

Type IV-HT construction requires at least 40 minutes of the 60-minute fire-resistance rating to be provided by noncombustible protection.

Question 22

The fire-resistance of a protected mass timber assembly is equivalent to the fire resistance time of the:

Options:

A.

mass timber itself.

B.

noncombustible protection.

C.

mass timber itself plus the finish rating time of the noncombustible protection.

D.

mass timber itself plus the added contribution time attributable to the noncombustible protection.

Question 23

The fire-resistance of a protected mass timber assembly is equivalent to the fire resistance time of the:

Options:

A.

mass timber itself.

B.

noncombustible protection.

C.

mass timber itself plus the finish rating time of the noncombustible protection.

D.

mass timber itself plus the added contribution time attributable to the noncombustible protection.

Question 24

According to UL Fire Resistance Directory, a “finish rating” is the time:

Options:

A.

assigned for gypsum board membranes in IBC Table 722.6.2(1)

B.

assigned for noncombustible protection in IBC Table 722.7.1(2)

C.

it takes the surface of wood nearest the fire but beneath the protective cover to reach a temperature rise of 250°F

D.

it takes the surface of wood nearest the fire but beneath the protective cover to reach a temperature rise of 325°F