UPS5000-A can significantly reduce the harmonic pollution to the power grid. In the case of linear full number, the input electric-hydrodynamic distortion nmi is ().
Is the channel type of the typical configuration of FusionModule800 a cold aisle or a hot aisle? ()
Which mode does Fusi onllodul e800 air conditioner configuration support? ()
Huawei FusionPower6000 is used with which of the following UPS products ().
What is the maximum IT load supported by the FusionModule2000 integrated UPS?
Which of the following models can be equipped with an external high-capacity battery charger for fast recharging? ()
The capacity management module of the NetEco management system can manage the resource capacity information in the computer room. Which of the following capacity elements is under the management of NetEco?
Fusionllodule2000 UPS is listed, configuration (
What sensor does FusionModule2000 use to detect whether the air conditioner is leaking?
The type of humidifier adopted by the row-level chilled water intelligent temperature control product NetCol5000-C032H is ( )
The total current of the battery pack is 1000A, and it is equipped with 3 sets of batteries. The most economical configuration of the cable from the main switch box to the sub-switch box is: ()
UPS2000-G-(6K- 20K) has a strong lightning protection design in the industry, lightning protection level (), surge protection level (), can avoid 90 failures caused by lightning strikes, and reliably
protect the exchange of back-end equipment. input port.
Among the following models, the one with the widest input frequency range is ()
Eaton and UPS5000-A 30kVA~120kVA similar models are ().
The NetEco6000 management system can manage the devices inside the FusionModule and outside the module at the same time. In the default recommended solution, the
devices inside the FusionModule use the ( ) collector to access the device, and the devices outside the module use the ( ) collector. to access the device?
The type of circuit breaker used in the sub-circuit of the PDU8000 precision power distribution cabinet. ()
What are the options in the typical configuration of FusionModule800?
What is the maximum IT load and how many power modules can the FusionModule2000 integrated UPS support?
NetEco. supports northbound integration, which of the following is not currently supported? ( ).
UPS2000-G 6-20k host operation interface is (), which can display system status in real time.
FusionModule2000 v3.0 version intelligent module status indication eLight function description is correct? (
UPS2000-G-(6K-20K) has a strong lightning protection design in the industry, lightning protection level (), surge protection level 0), which can avoid 90% failures caused by lightning strikes and
reliably protect the back-end equipment. AC input port.
UPS2000-G 6-20k host operation interface is (), which can display system status in real time ( )
What is the maximum power of the IT cabinet of FusionModule500&FusionModule800?
What are the incoming line methods supported by UPS5000-A-400/500K? ( )
What is the thickness of the insulation material of the FusionModule1000A V2R3 version?
UPS000-A/E 400KVA and above models are divided into standard version and enhanced version, of which the standard version comes standard with ( ) isolating switch
The NetCol5000-A042H full-cabinet row-level air-cooled variable frequency precision air conditioner supports a cooling capacity adjustment range of ( ), which can continuously cool under low load in the afternoon and avoid temperature
and humidity fluctuations and unit reliability problems caused by frequent start and stop.
The UPS5000-E has the function of adjusting the number of battery cells, which avoids the failure of a single battery to cause the replacement of the entire group, and solves the problem of difficult maintenance of
traditional UPS batteries. May I ask how many cells can be adjusted in the UPS5000-E (50kVA module)? ()
The configuration that UPS2000-G 20kVA can achieve does not include ( )
Which of the following options should be selected when the UPS5000-E selects the extended dry contact card and the back-feed protection card at the same time?
FusionPower6000 installation scenario ( ).
The NetCol5000-A042H full-cabinet row-level air-cooled variable frequency precision air conditioner supports a cooling capacity adjustment range of ( ), which can continuously cool under low load, avoiding temperature and humidity
fluctuations and unit reliability problems caused by frequent start and stop.
FusionModule1000A V2R3 version 40-foot IT solution can provide 7~8 IT cabinets
Huawei Precision Air Conditioner has an RS485 communication interface for remote inspection and parameter setting of the system: Modbus open protocol is provided to access the computer room
environmental monitoring system and reduce service costs
For fusionmodule2000 under different working conditions, there are two types of air conditioners ( )
FusionModule500&FusionModule800 remote web interface monitoring must be configured with unified network management software ( ).
PDU8000 precision power distribution cabinet supports monitoring of branch circuit phase current, active power, electric energy and branch circuit switch status.
Which of the following are indoor products of Huawei data center solutions
The UPS5000-E battery adopts the design of no neutral line, which is convenient for the battery to be used when replacing the tower.
The controller of fusionmodule2000 is called ECC800 ( )
UPS2000-G is an online double conversion UPS. In normal working state: the mains supply energy, the rectifier converts the alternating current into direct current, and the inverter converts
the rectified direct current into pure alternating current and provides it to the load, The charger charges the battery pack ()
The row-level air conditioners (25kw and 42kw) of Huawei FusionModule2000 v3.0 have the refrigerant detection function. (
ECC800 data room controller does not support log export ( )
PDu8000 precision power distribution cabinet supports single input and dual input ( ).
For an IT load of 80kW, a UPS system of 80kVA can meet the basic needs.
What is the cabinet depth of Huawei Micro Module 2000? (
Huawei air-cooled air conditioners (25kw and 42kw) one indoor unit corresponds to one outdoor unit
The backup time of UPS system is generally within 30min, so it is more reasonable to use the constant current method to calculate the battery capacity.
FusionModule1000A V2R3 version IT solution comes standard with cabinet spring damping device
The NetEco6000 management system supports virtualized deployment and adapts to the rhythm of future cloudization (
FusionModule supports access control by swiping card, but does not support two-way card swiping. ( ). /
The controller (ECC800) of Fusionmodule2000 adopts dual power supply ( )
To configure the UPS cable, it is necessary to consider the rated current of the UPS and the voltage drop on the line for selection
PDU8000 precision power distribution cabinet supports single input and dual input
NetCo18000-A013U 13kW small cooling capacity temperature control product adopts DC inverter compressor ( )
NetCol5000-A025H half-cabinet row-level inverter air-cooled precision air conditioner, NetCol5000-A042H full-cabinet row-level air-cooled inverter precision air conditioner, NetCol8000-C 2.0 series room-level
refrigerated underwater air supply precision air conditioner adopts a 7-inch touch color screen, which can be intuitively Vivid display of unit operation information.
UPS5000-E without built-in transformer
Huawei Netcol air-cooled air conditioner requires low temperature components when the outdoor temperature is lower than -20"C ()
UPS can be placed outside Fusionmodule2000 ( )
The FusionModule2000 integrated power distribution cabinet has two input switches of single-channel MCCB and ATS.
FusionModule1000A V2R3 version supports custom VESDA system
NetCol5000-c row-level chilled water intelligent temperature control product has a light-load dehumidification function, which can meet the reliable dehumidification under a minimum load of 10%, and avoid the hidden danger of
condensation in a low-load and high-mix environment. ()
NetCo15000-C row-level chilled water intelligent cooling product supports return air, supply air, cold aisle, hot aisle and other types of temperature and humidity control ( )
The NetEco management system realizes the video surveillance function of the equipment room by integrating the Huawei eSpace VCN video solution.
The NeEco management system supports remote notification of alarms through SMS, email, etc., prompting users to deal with alarms as soon as possible.
UPS5000-E about the characteristics of intelligence, which are correct? ()
In the UPS5000 configurator, the optional module types are (
When the distance between the outdoor unit and the seaside is 0.5km~3.7km, you need to configure the () outdoor unit
The standard communication methods of UPS5000-E are ( )
What specifications does the FusionModule500 UPS have? (
If the customer has high requirements on the availability of the management system and requires that the normal use of the system is not affected by a single point of failure of the hardware, the NetEco management system can provide a
high-availability solution of dual-system backup. What are the hardware resources required by NetEco in the dual-computer solution? (
In the FusionModule2000 configurator, what are the common cabinet specifications (
The cooling capacity of intelligent temperature control products can only be determined when the working conditions are clarified. There are many factors that affect the cooling capacity. For example, when selecting a row-level chilled water intelligent temperature control
product, at least information such as ( ) must be specified.
UPS5000-A has reliable, efficient and simple design features, then which of the following statements is true about UPSS000-A-400/500K? () (multiple choice)
What is the height of the FusionModule2000 cabinet in mm? ( )
The NetEco management system combines the operation and maintenance experience of Huawei I and the process department to launch an electronic remote maintenance module to help the operation and maintenance personnel to complete the daily operation and inspection of the computer room. Which of the following functions can be achieved: (multiple choice)
The characteristics of the compressor used by Huawei NetCo15000-A include: ( ).
Why are FusionModule500&FusionModule800 generally recommended to customers for typical configuration solutions? (Multiple choices)
For large-scale data center power distribution rooms, when configuring upper air conditioners, the elements for selecting hood air supply and air duct air supply mainly include ().(Multiple choices)
Which of the following conditions are required to calculate the rated input current of the UPS: ( ) (multiple choice)
In UPS5000S, the adjustable range of the number of battery cells in a single group is
The management software recommends that the optimal location of the server installation is not considered ( ).
Which of the following statements are true about the iBattery battery management system? ()
Which of the following voltage systems does the UPS5000-E support?
Using UPS5000-E (50kVA power module), the actual load is 160kW, the rack 1+1 redundancy, the single-machine backup power scheme is adopted, the backup power scheme for each machine, each rack has 3
sets of batteries, each set of 40 cells, The main switch box capacity is (
Configure the UPS system scheme, which of the following factors need to be considered in the calculation scheme ( )
The root standard stipulates that the voltage drop of the AC cable should be controlled within 3%. It is recommended that the voltage drop of the AC cable should be controlled within ( ) when designing the UPS system.
Huawei's main temperature control solution for small and medium-sized computer rooms is:
What kind of access control can the rear door of the FusionModule2000 cabinet support? A Mechanical code lock B IC card swipe access control C Three-in-one access control D None of the above Answers: D 216.
The NetEco6000 management system can provide energy efficiency management functions. Which of the following functions are supported? (multiple choice)
UPS5000-E-500K Regarding efficiency, which of the following options is correct? ()
FusionModule1000A V2R3 version prefabricated integrated data center has Najishen solution (multiple choice)
When the NetCol8000-C room-level chilled water intelligent temperature control product is booted, our ( ) model will be used first.
What are the requirements for power supply and energy supply for "digitization of all industries"? /
In PDU8000, what are the optional functions (
Regarding fluorine pump type energy-saving air-conditioning products, which of the following statements is correct ((multiple choice)
In the air-conditioning system, the correct statement of the flow direction of the refrigerant is (). In this agenda, Binleng has undergone a process of changing from high pressure gas state, high pressure liquid state, low pressure liquid state,
and low pressure gas state. ()