Pre-Summer Sale Limited Time Flat 70% Discount offer - Ends in 0d 00h 00m 00s - Coupon code: 70spcl

Huawei H13-624_V5.5 HCIP-Storage V5.5 Exam Practice Test

Page: 1 / 13
Total 125 questions

HCIP-Storage V5.5 Questions and Answers

Question 1

Assume an industry customer purchased several Huawei flash storage devices for service deployment. During routine management, an engineer found that the host bus adapter (HBA) driver version of the host is outdated and the number of concurrent HBAs was insufficient. As a result, the latency on the host differs greatly from that on the storage side. Which of the following measures can the engineer take to optimize performance?

Options:

A.

Use the management software provided by the HBA vendor to query and modify the number of concurrent HBAs.

B.

Upgrade the HBA driver to the latest version.

C.

Change the load balancing algorithm of the multipathing software to min-task.

D.

Change the cache prefetch policy to constant prefetch.

Question 2

Assume a financial customer purchases several Huawei scale-out storage devices for service deployment. Unstructured services require multiple network planes. Which statement about the network planes is false?

Options:

A.

The internal management network is used for communication between storage and management nodes, including deployment and upgrade, resource configuration, performance alarm reporting, and certificate and key update.

B.

For the file service in the Distributed Parallel Client (DPC) scenario, the back-end storage network is available for communication with compute nodes to process communication data between the DPC and Object Storage Device (OSD).

C.

The management network is used for system management and maintenance. It is connected to the customer’s management network.

D.

The service network is connected to the customer’s application system and accesses the storage through the S3, HDFS, NFS, CIFS, and POSIX interfaces.

Question 3

A school has purchased two Huawei OceanStor Pacific series storage devices for service deployment. An engineer wants to configure the distributed parallel client (DPC) on the storage devices. Which of the following statements is false about the engineer's configuration?

Options:

A.

If upper-layer services require high data security, the engineer needs to set the storage pool type to "Self-encrypting" when creating a converged storage pool.

B.

Before creating a converged storage pool, the engineer must enable the file service for nodes on DeviceManager.

C.

When creating a namespace, the engineer needs to select a security style and application type.

D.

When the storage network is a Remote Direct Memory Access over Converged Ethernet (RoCE) network, the engineer can run the "systemctl stop lldpad.service" command to disable the lldpad service.

Question 4

A financial customer purchases a Huawei OceanStor Pacific 9950 storage device for service deployment. Engineers have configured basic block storage services on the device. During an O & M management process, an engineer needs to modify the attributes of a storage pool. Which of the following attributes will not be modified?

Options:

A.

Hot spare policy of the storage pool

B.

Storage pool name

C.

Actual location of the storage pool

D.

Capacity alarm threshold

Question 5

Assume a financial customer purchases a Huawei OceanStor Pacific scale-out storage system for future service deployment. Which statement is false about software installation of the storage system?

Options:

A.

During block service installation, if management nodes are deployed where compute and storage nodes are converged, the number of vCPUs on each converged compute and storage node must be greater than or equal to 20.

B.

During block service installation, if converged deployment of storage and compute nodes is required, the difference between the disk quantities on any two nodes in the same storage pool cannot be greater than 2 or 30% of the disk quantity on the node having most disks.

C.

If wizard-based software installation is used, an engineer must manually add nodes, configure networks, and create a control cluster on DeviceManager, and then install the OceanStor Pacific series software.

D.

To install the Distributed Parallel Client (DPC), the memory required for running the DPC software on a compute node must be greater than or equal to 20 GB.

Question 6

When delivering a Huawel OceanStor Pacific scale-out storage project, Huawei engineers Introduced the end-to-end load balancing capabllty supported by the scale-out storage to the customer. Which of the following statements are false about the load balancing capability?

Options:

A.

The route-based hash policy of the persistence layer is different from that of the service layer. The route-based hash policy of the persistence layer is implemented based on weights, while that of the service layer is implemented based on STORE DHT.

B.

Unstructured and structured services at the service layer have different route-based hash policies. However, both unstructured and structured services are mapped based on the same basic routing model.

C.

In load balancing at the semantic layer, a directory is divided into 256 partitions by default and can be adjusted to a maximum of 512 partitions.

D.

Routes at the service layer balance storage space and accelerate fault reconstruction.

Question 7

When delivering a flash storage project, Huawei engineers introduced the trusted and secure boot technology of flash storage hardware to the customer. Which of the following statements are true about this technology?

Options:

A.

This technology uses digital signatures to verify firmware integrity and prevent firmware and operating systems from being tampered with.

B.

After a device is powered on, the initial startup module starts, and verification is performed level by level. If the verification is successful, the device starts.

C.

During secure boot, the RSA engine verifies the status of the software signature certificate and then verifies the Grub signature public key.

D.

In the overall startup process, Grub needs to be verified and loaded first. After the loading is complete, the Grub signature public key is verified.

Question 8

To analyze disk performance, we can first use tools (such as free, top, vmstat, and pidstat) that support many indicators, and then determine the I/O source and analyze the file system and process I/Os.

Options:

A.

TRUE

B.

FALSE

Question 9

Assume a scientific research Industry customer purchased several Huavvel OceanStor Pacific series scale-out storage devices for service deployment, and an engineer has configured the file service in the Distributed Parallel Client (DPC) scenario on the storage devices. To meet high performance requirements of front end services, the engineer wants to enable the CPU performance mode for the DPC node using the CU. Which of the following commands can be used to enable the CPU performance mode?

Options:

A.

cpupower frequency-info

B.

cpupower frequency-set -g performance

C.

change service ndmp_restart_servlce

D.

change pms converged_qos_policy

Question 10

An Industry customer purchases several Huawei flash storage devices for service deployment. During an inspection, an engineer finds that some storage components are faulty and need to be removed and replaced. Which of the following statements Is true about the part removal and replacement?

Options:

A.

The interface modules and system subracks of the storage device can be replaced independently.

B.

The CPUs of the storage device cannot be replaced independently, but can be removed independently.

C.

The memory modules and system disks of the storage device can be removed and replaced independently.

D.

The coin batteries of the storage device cannot be replaced or removed.

Question 11

Assume an enterprise customer purchased several Huawei flash storage devices for service deployment. An engineer needs to configure Syslog notification on the storage system. Which of the following statements are false about configuration operations?

Options:

A.

During the configuration, the engineer needs to configure the SNMP protocol and USM users in the storage system for receiving and querying system alarms.

B.

To view the display format of Syslog content, the engineer can run the "show notification syslog" command.

C.

To change the display format of Syslog content to CEF, the engineer can run the "change syslog-notification format_type=cef" command.

D.

If certificates and CA certificates are generated on the Syslog server, the engineer does not need to perform any operation in the storage system.

Question 12

In Huawei all-flash storage, the SmartDedupe and SmartCompression features reduce redundant data space consumption and improve the transmission and storage efficiency of a storage system. Which of the following statements about the features is false?

Options:

A.

Post-process compression means that data is first written to storage media and then read for compression.

B.

During inline deduplication, the system divides data into blocks and then calculates fingerprints for the blocks.

C.

During similarity-based deduplication in the background, the system does not divide data into blocks and can directly calculate similar fingerprints.

D.

Backup storage supports deduplication and compression of file systems.

Question 13

When delivering a flash storage project, Huawei engineers Introduced the SmartMuIti-Tenant feature of flash storage to the customer. Which of the following statements are true about SmartMulti Tenant?

Options:

A.

A super administrator can force itself, other super administrators, lightweight directory access protocol (LDAP) users, or LDAP user groups to change their passwords upon the next login.

B.

After a system is upgraded to support the SmartMulti-Tenant feature, all LUNs, file systems, and ports in the original system are allocated to the internal system vStore "System_vStore."

C.

To query system role information, the customer can run the "show role system" command.

D.

In flash storage, only a super administrator can modify vStore information, and the internal system vStore "System_vStore" cannot be modified.

Question 14

uses Huawei's optimized FlexFC algorithm. This algorithm allows the system to tolerate simultaneous failures of three disks, greatly shortening the reconstruction time and

effectively addressing data protection challenges in the large capacity disk era.

Options:

Question 15

A financial customer purchases a Huawei flash storage device for subsequent service deployment. During storage configuration, an administrator finds that LUNs mapped to an application server cannot be detected on the application server. Which of the following are possible causes of this exception?

Options:

A.

The storage pool is faulty.

B.

In HP-UX, the application server does not have a LUN mapping whose host LUN ID is 0.

C.

In UNIX or Linux, a device node file is lost.

D.

The serial port connection parameters are incorrectly set.

Question 16

An airport customer has purchased several Huawei OceanStor Pacific scale-out storage devices for service deployment. To ensure service reliability, an engineer has configured the HyperReplication feature on the storage devices and established a remote replication pair between the namespaces of the primary and secondary storage systems. Which of the following statements is true about the running statuses of the remote replication pair?

Options:

A.

If the running status of the remote replication pair is "Synchronizing", this indicates that data is being synchronized from the primary namespace to the secondary namespace. In this case, the engineer can enable the protection for secondary resources on the secondary storage system.

B.

If the running status of the remote replication pair is "Interrupted", this indicates that an internal I/O error has occurred or the remote replication link is down. As a result, the pair relationship is interrupted.

C.

If the running status of the remote replication pair is "Split", this indicates that the remote replication link is down or an internal I/O error has occurred. In this case, the pair cannot be synchronized or deleted.

D.

If the running status of the remote replication pair is "To be recovered", this indicates that the internal I/O error of the remote replication pair has been rectified. Data consistency between the primary and secondary storage systems is guaranteed by automatic synchronization.

Question 17

In Huawei flash storage. If you want to apply the HyperCDP feature to a LUN, you are advised to reserve 5% to 10% of the LUN capacity in the storage pool to which the I UN belongs for storing HyperCDP object data, and configure a protection capacity threshold for the storage pool to stop creating HyperCDP objects or even automatically delete HyperCDP objects when the storage pool capacity is insufficient.

Options:

A.

TRUE

B.

FALSE

Question 18

In OceanStor Pacific series storage systems, if a node or disk is faulty, data reconstruction in the disk pool can be automatically performed after 15 minutes.

Options:

A.

TRUE

B.

FALSE

Question 19

Assume a government customer purchased several Huawei scale-out storage devices for service deployment. An engineer needs to configure file services in standard protocol scenarios. Which of the following actions does not need to be performed by the engineer during the configuration?

Options:

A.

Install DPC.

B.

Create a converged storage pool.

C.

Create namespaces.

D.

Enable the file service for nodes.

Question 20

To improve service availability, a manufacturing customer has purchased multiple Huawei flash storage devices and deployed active-active and remote backup services on them. In this case, if the link bandwidth is too low or the concurrent processing capability is insufficient, the active-active service may be faulty, but the remote backup service is not affected.

Options:

A.

TRUE

B.

FALSE

Question 21

SPC certification is a SAN performance test benchmark for third-party evaluation. Which of the following statements is true about SPC certification scenarios?

Options:

A.

SPC-2 applies to scenarios where random small I/Os are quickly responded.

B.

SPC-1 applies to scenarios of sequential large I/O access.

C.

SPC-2 applies to scenarios of sequential large I/O access.

D.

SPC-2 is used to test the SAN array performance in the OLPT, database, and email application scenarios.

Question 22

When deploying a Huawei converged storage system, engineer A uses the UltraPath software. Which of the following statements are false about the load balancing algorithms of UltraPath?

Options:

A.

The min-queue-depth algorithm refers to the minimum queue depth algorithm. UltraPath is configured with this algorithm by default.

B.

Round robin is a min-task algorithm and can be used in scenarios where service I/O model data blocks delivered by the host are large.

C.

The min-task algorithm is a round robin algorithm and can be used in scenarios where the service I/O models delivered by the host have little difference.

D.

The algorithms fall into three types: min-queue-depth, round-robin, and min-task.

Question 23

Assume a financial customer purchased several Huawei scale-out storage devices for deploying the video surveillance service. This service has high requirements on performance. Therefore, the cache write policy must be set to write-through for the storage devices.

Options:

A.

TRUE

B.

FALSE

Question 24

An enterprise customer has purchased a Huawei OceanStor Pacific scale-out storage system for service configuration. An engineer wants to deploy the NFS file sharing service on the storage system and configure the HyperReplicatlon feature. Which of the following configuration operations are correct?

Options:

A.

When configuring HyperReplication, the engineer needs to configure the replication network route information on the primary storage system. The replication network route does not need to be configured on the secondary storage system.

B.

To use the NFSv4.0 protocol for share access, the engineer can run the "change service nfs_config nfsv40_status=enable account_name=?" command to enable the NFSv4.0 service.

C.

After a converged storage pool is created, the engineer needs to enable the file service. The HDFS or object service does not have to be enabled.

D.

When configuring HyperReplication, the engineer needs to create a remote replication pair on both the primary and secondary storage systems and then add a remote device.

Question 25

If a performance Issue occurs in Huawei flash storage, an engineer can perform optimization operations according to the storage performance optimization process. Which of the following statements is false about the performance optimization process?

Options:

A.

In the information collection phase, the engineer needs to collect basic information about applications and data, such as the impact of application configurations on data, data size, and read/write ratio.

B.

In the test and application phase, the engineer needs to test the configurations to check whether the optimization objective is achieved. If yes, the engineer can put the system into use.

C.

In the optimization analysis phase, the engineer needs to specify the performance optimization objective, find out the performance bottleneck, and identify the parts that play a key role in Improving the system performance.

D.

In the optimization operation phase, the engineer needs to deploy DR for the service system, and needs to modify multiple configuration at a time during the optimization configuration.

Question 26

A faulty storage hardware module needs to be replaced. Which of the following components can be replaced online?

Options:

A.

Controller enclosure backplane

B.

BBU

C.

Disk

D.

Interface module

Question 27

Huawei OceanProtect Appliance provides strong data protection capabilities. Which of the following statements is true about the functional architecture of the Appliance?

Options:

A.

ProtectManager is a data flow module that performs data backup, restoration, replication, archive, and copy mounting.

B.

File system management and protocol access are implemented by the data protection layer.

C.

During data protection, the Appliance can protect application data without backup agents.

D.

DataEnable Engine is a data enabling module for global search and data anonymization.

Question 28

When delivering a flash storage project, Huawei engineers introduced the arbitration mechanism of HyperMetro to the customer. Which of the following statements is false about the arbitration modes?

Options:

A.

If no quorum server is configured, HyperMetro works in static priority mode. When an arbitration occurs, the preferred site wins the arbitration and provides services.

B.

In static priority mode, if the preferred site of a HyperMetro pair breaks down, the non-preferred site does not automatically take over HyperMetro services. As a result, the services stop, and the customer must forcibly start the services at the non-preferred site.

C.

In quorum server mode, the quorum server can be deployed only on physical machines and not on virtual machines.

D.

In quorum server mode, if the link between storage systems is down, each storage system sends an arbitration request to the quorum server.

Question 29

In Huawei flash storage, the administrator rote has full control permissions on storage devices. The administrator can power on, power off, and restart devices and create users of different roles.

Options:

A.

TRUE

B.

FALSE

Question 30

After purchasing a Huawei OceanStor Dorado series storage system, a customer needs to configure basic storage services in the storage system. Which of the following operations are optional in the basic service configuration?

Options:

A.

Configuring connectivity between a host and the storage system

B.

Creating a port group

C.

Creating a mapping

D.

Creating a LUN group

Question 31

During routine management of Huawei flash storage, an engineer can use the "show license_active" command to query information about activated licenses.

Options:

A.

TRUE

B.

FALSE

Question 32

A company has purchased multiple Huawei OceanStor Pacific series devices to deploy the remote replication service. During routine operation and maintenance, an administrator needs to manage the replication cluster. Which of the following statements are true about a replication cluster?

Options:

A.

Capacity reduction of a replication cluster can be performed only when the number of nodes is greater than or equal to 4.

B.

The name of a replication cluster for which cross-site disaster recovery is enabled cannot be changed, but the replication cluster can be deleted.

C.

When the capacity of a replication cluster is expanded, the replication network can share the same subnet with other networks.

D.

When an IP address of a replication cluster is changed, if a node in the replication cluster uses multiple ports and different replication ports are configured with IP addresses in the same network segment, the original policy-based route must be deleted before configuring a new policy-based route.

Question 33

During routine inspection, an engineer of a bank finds that an interface module of a Huawei flash storage device is faulty. In this case, the engineer can directly remove and insert the interface module without any pre-operations.

Options:

A.

TRUE

B.

FALSE

Question 34

Assume an Industry customer purchased a Huawel flash storage device for service deployment. After a fault occurs, an engineer needs to use the CLI to view bit error Information of front end host ports for troubleshooting. Which of the following commands cannot be used for this purpose?

Options:

A.

show coexist-forward-switch

B.

show controller io io_type=frontEnd controller_id=XX

C.

show port biLerror

D.

show host-port error

Question 35

A financial customer has purchased several Huawei OceanStor Pacific 9550 storage systems. When configuring basic object services on the storage systems, an engineer discovers that the object service cannot be enabled for storage nodes. Which of the following is not a possible cause?

Options:

A.

The engineer has manually adjusted the time of the cluster nodes. As a result, the conflict handling is different.

B.

NTP synchronization is not configured for the cluster, and different NTP time sources are used.

C.

Namespaces with the same name have been created under the same account.

D.

The Network Time Protocol (NTP) clock in the storage cluster is inconsistent with the clock of the client that accesses object services.

Question 36

Similar to the alarm analysis method, the replacement method can be used to locate and rectify any type of faults for Huawei converged storage, and has no special requirement for maintenance personnel.

Options:

A.

TRUE

B.

FALSE

Question 37

During routine O & M, an engineer finds that the system time of multiple Huawei flash storage devices Is Incorrect, and needs to correct the system time. Which of the following Is not a possible impact of changing the system time?

Options:

A.

If the new device time is later than the deadline for saving historical performance data, the system will no longer save historical performance data.

B.

Changing the device time will affect the life spans of disks and controllers, which may trigger alarms indicating that the hardware life span expires or hardware is aging.

C.

If the new system time is later than the user-defined password expiration date, the system may force the user to change the login password.

D.

If the new device time is later than the certificate validity period, the certificate will expire.

Page: 1 / 13
Total 125 questions