Summer Sale Limited Time Flat 70% Discount offer - Ends in 0d 00h 00m 00s - Coupon code: 70spcl

DELL EMC D-PE-OE-01 Dell PowerEdge Operate v2 Exam Exam Practice Test

Page: 1 / 5
Total 50 questions

Dell PowerEdge Operate v2 Exam Questions and Answers

Question 1

A new Dell customer is ordering servers that have very specific firmware dependencies. Any replaced parts of the same type must match the replaced original part identically. The procedure must be as simple as possible with minimal risk. What action should a technician take to accomplish this goal?

Options:

A.

Install and configure a repository manager

B.

Enable the Match Firmware of Replaced Part setting in BIOS

C.

Configure servers to access the remote firmware repository

D.

Enable the Collect System Inventory On Restart attribute

Question 2

After updating BIOS and NIC firmware using Lifecycle Controller, a PowerEdge server boots into Lifecycle Controller instead of the OS, although the OS disks are intact. What is the most likely root cause?

Options:

A.

Boot mode was changed

B.

RAID metadata corruption

C.

Secure Boot certificates expired

D.

iDRAC lost network connectivity

Question 3

You are in a dark site with a PowerEdge server that shows an amber light. iDRAC Is not configured for network access but the OS is installed and has RACADM for access to the iDRAC card. What RACADM command can be used to help identify the cause of the amber light?

Options:

A.

getsel

B.

getssninfo

C.

getsysinfo

D.

get led

Question 4

You have installed RHEL and reboot the PowerEdge server. You see this output displayed when the system boots:

Booting from PCIe SSD in Slot 5 Index 0: Red Hat Enterprise Linux

UEFI0073: unable to boot PCIe SSD in slot 5 Index 0: Red Hat Enterprise Linux because of the security Boot policy.

Boot Failed: PCIe SSD in Slot 5 Index 0: Red Hat Enterprise Linux

Booting from Disk connected to front USB 1: Cruzer Fit

UEFI0073: Unable to boot Disk connected to front USB 1: Cruzer Fit because of the Security Boot policy.

Boot Failed: Disk connected to front USB 1: Cruzer Fit

No boot device available or Operating System detected.

Please ensure a compatible bootable media is available.

Available Actions:

Fl to Continue and Retry Boot Order

F2 for System Setup (BIOS)

Fll for Boot Manager

Which component is the cause of the error?

Options:

A.

iDRAC Service Module

B.

BOSS-N1 controller card

C.

Trusted Platform Module

D.

IDM/Personality Module

Question 5

During a physical Inspection, the System Status LED Is blinking blue. What does this indicate?

Options:

A.

Hardware fault detected

B.

PSU redundancy lost

C.

Thermal threshold exceeded

D.

System is being identified

Question 6

A PowerEdge R760 powers on with no video output. You decide to perform a Minimum-to-POST test. Which configuration correctly represents a valid Minimum-to-POST?

Options:

A.

One CPU with all associated DIMM, one PSU, no PCIe card

B.

One CPU, one DIMM in the primary channel, one PSU, no PCIe card

C.

Two CPUs installed with all DIMMs populated, one PCIe card

D.

One CPU with all associated DIMM, one PSU, one PCIe card

Question 7

An administrator wants to ensure continuous visibility into the hardware health of a Dell PowerEdge server and be notified immediately if a component begins to fail. Using iDRAC, what action should be taken to meet these requirements?

Options:

A.

Monitor hardware health only through the operating system tools

B.

Log in to iDRAC only after the operating system reports a failure

C.

Configure iDRAC hardware health monitoring with automated alerting

D.

Disable system alerts to reduce unnecessary notifications

Question 8

Your company is decommissioning a PowerEdge 16G server to a 17G server. All the disks in the 16G server are SEDs. Your security team requires that the server is securely retired. Which feature can be used to comply with the security requirement?

Options:

A.

Use LifeCycle Controller ISE feature

B.

Enable Secure Boot in BIOS

C.

Enable Lockdown Mode in iDRAC

D.

Use SCV application feature

Question 9

A company with a 17G PowerEdge Server model requires these features: Essential System Management Features; Core Features, Automation, Virtual and Security Enhancements; Enterprise Features with added telemetry, thermal management, support for accelerators (GPU and DPU), and advanced Air and Liquid Cooling. Which iDRAC license is the minimum required to meet these requirements?

Options:

A.

Datacenter

B.

Core

C.

Enterprise

D.

Express

Question 10

After adding DIMMs on a PowerEdge R760, the server powers on, fans spin, but the system does not reach POST. The LCD shows no error. What two things should be done to resolve this Issue?

Options:

A.

Reseat memory

B.

Replace the system board

C.

Verify DIMM population

D.

Update the BIOS

E.

Clear SEL logs

Question 11

A Dell PowerEdge server has Temperature Alert Configuration set up in iDRAC. A Test Event was executed, and email alerts appeared to be delivered successfully. However, a few days later, the server unexpectedly rebooted. Upon inspection, CPU temperatures had exceeded the configured threshold. What is a possible reason IDRAC failed to alert the administrator about the high temperature?

Options:

A.

iDRAC only sends alerts for Critical events or higher.

B.

Although the Temperature Alert was configured, it was not fully activated.

C.

Test Events verify alert delivery but do not trigger actual hardware alerts.

D.

The reboot may have bypassed iDRAC alert mechanisms.

Question 12

A PowerEdge R750 reports “Degraded" status with a question mark next to several components in iDRAC, but all OS-level monitoring tools show no hardware errors. What should be checked first to identify the cause?

Options:

A.

System Event Log (SEL)

B.

BIOS boot mode

C.

Lifecycle Controller firmware version

D.

RAID virtual disk layout

Question 13

In order to Improve efficiency of the Data Center, the IT department has been tasked with auditing the health and performance, including any sensor alerts, for all Dell servers from the past quarter. Which two basic actions must be taken on the servers in order to obtain the requested information?

Options:

A.

Apply iDRAC Enterprise License

B.

Acquire appropriate Login privilege

C.

Set iDRAC networking to use DHCP

D.

Enable RACADM

Question 14

A system administrator is tasked with upgrading the environment to VMware vSphere 8 and manage the latest Dell PowerEdge servers. The company wants to simplify operations, reduce costs, and avoid using multiple tools for physical and virtual infrastructure management. Which integration should the administrator implement to meet these requirements?

Options:

A.

Use standalone OpenManage Server Administrator

B.

Continue using OMIW for VMware integration

C.

Deploy OpenManage Enterprise with VMware vCenter

D.

Implement manual firmware updates and health checks

Question 15

A system administrator must update the virtual console security settings on their PowerEdge server to comply with company standards. The company requires strong encryption and secure access policies. Which setting meets these requirements?

Options:

A.

Use a strong password

B.

Disable SSL encryption for faster performance

C.

Configure an acceptable timeout value

D.

Set SSL encryption to 256-bit or higher

Page: 1 / 5
Total 50 questions